Skip to content
Hengchang Technology

Jump starter cable

EC5 jump starter cable — copper, clamp-ready, reverse-polarity protected

An EC5 jump starter cable connects a portable jump starter to the battery through two clamps. Ours uses 100% copper in 10 AWG or 8 AWG, roughly 37 cm per lead, with a protection module that cuts the circuit if the clamps are reversed.

  • 100% copper conductor, 10 AWG or 8 AWG
  • Reverse-polarity protection built into the lead
  • Red 370 mm / black 340 mm, folded for compact retail packing
  • OEM from 5,000 sets

Specification

What you get in one set

Two clamps, two leads and the in-line protection module. Both gauges share the same connector, clamp and length so a carton can mix them without changing the packing.

EC5 jump starter cable specification, 10 AWG and 8 AWG
Item10 AWG8 AWG
Cross-section5.26 mm²8.37 mm²
Conductor100% copper100% copper
ConnectorEC5EC5
Lead lengthRed 370 mm / black 340 mmRed 370 mm / black 340 mm
ClampsInsulated battery clampsInsulated battery clamps
Compatibility12 V and 16.8 V jump starters12 V and 16.8 V jump starters
ProtectionReverse-polarity auto disconnectReverse-polarity auto disconnect
OEM MOQ5,000 sets5,000 sets

Length is measured pin to clamp. Tell us the pack you are building for and we will confirm the set that matches it before a sample is cut.

Packing design

Why the red and black leads are not the same length

Buyers ask about it in every first call, so it is worth stating plainly: the uneven pair is a packing decision, not a cutting error.

  • The two leads are deliberately unequal — red 370 mm, black 340 mm.
  • The offset lets the pair fold flat into a compact retail pouch, so the blister or colour box is smaller.
  • A smaller carton means more sets per export carton, which lowers packing cost and freight per unit.
  • Both leads are cut to a fixed length by machine, so every set in a carton measures the same.

What it saves on a full carton

A folded pair with a 30 mm offset sits flatter in the pouch than two equal leads, so the pouch, the inner box and the export carton all shrink with it. On a full container the difference is paid once in packing material and again in freight, which is why the offset has stayed in the drawing.

If your packaging needs equal leads, say so at the sample stage. The length is a cutting setting, not a tooling change.

Gauge

8 AWG or 10 AWG: what the extra copper buys

Both gauges fit the same EC5 plug and the same clamps. The difference only shows up in the first seconds of cranking.

10 AWG — 5.26 mm²

The volume choice for small petrol engines, motorcycles, garden equipment and packs sold into retail at a price point. Lighter, cheaper to ship, and enough for a warm engine.

8 AWG — 8.37 mm²

About 59% more copper than 10 AWG. Lower resistance, so less voltage drop reaches the starter. The choice for diesel, large-displacement petrol and cold-climate packs, where a thin lead is what makes a good pack look weak.

Sizing a lead is a current-and-time question, not a numbers-up question: the cable only has to survive the crank, and the crank only lasts seconds. We will quote both gauges against your pack so you can compare landed cost rather than copper weight.

Protection

Reversed clamps cut the circuit instead of the pack

If the clamps are connected to the wrong terminals, the module cuts the circuit instead of letting current flow. Correct the connection and the cable works normally again. There is no fuse to replace and no button to reset — the protection is in the lead, so it travels with the product and does not depend on the user reading a manual.

EC5 jump starter cables with insulated battery clamps on the assembly line

Inside the build

Five checks between the cutter and the carton

The clamp, the wire gauge and the cable length are the three things a buyer can verify by hand. Everything on the line is arranged so those three are checked before packing.

  • Conductor cut to length, then stripped and crimped to the EC5 terminal.
  • Crimp height is checked on the line — a loose crimp is a hot joint under starting current.
  • The protection module is soldered in-line, then the assembly is sleeved.
  • Each set is continuity-checked and the protection cut-out is tripped and reset once.
  • Clamps are fitted, the pair is folded and bagged, then packed to the carton count.

Related

Same factory, same copper discipline

The EC5 set is built on the same crimp, test and packing line as our other cable assemblies.

USB-C cable assemblies

240 W E-Marker assemblies and USB4 data cables, terminated and tested in the same plant.

More articles

Fiber optic patch cords

Insertion loss and return loss measured on every cord, the same habit applied to copper.

More articles

XT30 / XT60 / XT90 connectors

The high-current connector family the EC5 body belongs to, 20 A to 45 A with PCB and solder versions.

More articles

How to write a cable specification

The questions to settle before a sample is cut, whatever the cable carries.

More articles

Buyer questions

Three things buyers ask first

Will this cable fit my jump starter?

It uses the EC5 connector and works with 12 V and 16.8 V portable jump starters that accept EC5. Check the socket on your pack before ordering: EC5 is a keyed plug, so a pack built around a different connector will not mate. Send us the pack model and we will confirm the match before you place a sample order.

What is the difference between 10 AWG and 8 AWG?

8 AWG has 8.37 mm² of copper against 5.26 mm² for 10 AWG, about 59% more. At the same length that means lower resistance and less voltage drop during the few seconds of cranking, which matters most on diesel engines and large-displacement petrol engines. 10 AWG is the cheaper option where the pack is used on small engines.

What happens if I connect the clamps the wrong way?

If the clamps are connected to the wrong terminals, the module cuts the circuit instead of letting current flow. Correct the connection and the cable works normally again — there is no fuse to replace and no reset button to press. This protects the jump starter pack, which is the expensive part of the kit.

Building a jump starter kit?

Send the pack model and the annual volume and we will come back with the gauge, the clamp and the packing that fit it. wangyazhong@hengchangtech.com